Oil tempering of pressure casting moulds
When using oil as the tempering medium, flow temperatures of up to 350°C can be reached in the pressure casting moulds. Especially in the field of moulds, which require higher temperatures, in order to manufacture a high-quality product, oil units are the best solution to control your heat management.
The units are available as one- or two circuit units.
Oil tempering of pressure casting moulds
Thanks to our patented heating and cooling design we can guarantee the highest efficiency in the transfer tof heat and the lowest radiation loss.
Combined with our IE3 drive motor the highest energy efficiency is reached when operating our units.
3201 bis 250°C
Circuits | |
Number | 1 |
Flow temperature | |
max. | 250 °C |
Heating capacity at 400V | |
Standard | 10 KW |
Standard | 20 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM1 |
max. flow quantity | 60 l/min |
max. pressure | 7,5 bar |
Capacity | 1,1 KW |
Oil tank | |
Capacity | 25 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 1/2" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 380 mm |
Height | 1120 mm |
Depth | 1120 mm |
Weight | |
Standard | 142 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
3212 bis 250°C
Circuits | |
Number | 2 |
Flow temperature | |
max. | 250 °C |
Heating capacity at 400V | |
Standard | 10 KW |
Standard | 20 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM1 |
max. flow quantity | 60 l/min |
max. pressure | 7,5 bar |
Capacity | 1,1 KW |
Oil tank | |
Capacity | 25 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 1/2" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 500 mm |
Height | 1300 mm |
Depth | 1120 mm |
Weight | |
Standard | 280 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
4201 bis 320°C
Circuits | |
Number | 1 |
Flow temperature | |
max. | 320 °C |
Heating capacity at 400V | |
Standard | 10 KW |
Standard | 20 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM1 |
max. flow quantity | 60 l/min |
max. pressure | 7,5 bar |
Capacity | 1,1 KW |
Oil tank | |
Capacity | 25 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 1/2" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 380 mm |
Height | 1120 mm |
Depth | 1120 mm |
Weight | |
Standard | 142 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
4212 bis 320°C
Circuits | |
Number | 2 |
Flow temperature | |
max. | 320 °C |
Heating capacity at 400V | |
Standard | 10 KW |
Standard | 20 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM1 |
max. flow quantity | 60 l/min |
max. pressure | 7,5 bar |
Capacity | 1,1 KW |
Oil tank | |
Capacity | 25 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 1/2" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 500 mm |
Height | 1300 mm |
Depth | 1120 mm |
Weight | |
Standard | 286 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
5201 bis 350°C
Circuits | |
Number | 1 |
Flow temperature | |
max. | 350 °C |
Heating capacity at 400V | |
Standard | 10 KW |
Standard | 20 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM3 |
max. flow quantity | 80 l/min |
max. pressure | 11 bar |
Capacity | 2,8 KW |
Oil tank | |
Capacity | 25 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 3/4" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 380 mm |
Height | 1120 mm |
Depth | 1120 mm |
Weight | |
Standard | 185 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
5211 bis 350°C
Circuits | |
Number | 1 |
Flow temperature | |
max. | 350 °C |
Heating capacity at 400V | |
Standard | 30 KW |
Standard | 40 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Cool water quantity | 20 l/min |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM3 |
max. flow quantity | 80 l/min |
max. pressure | 11 bar |
Capacity | 2,8 KW |
Oil tank | |
Capacity | 35 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 3/4" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 500 mm |
Height | 1300 mm |
Depth | 1120 mm |
Weight | |
Standard | 260 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
5212 bis 350°C
Circuits | |
Number | 2 |
Flow temperature | |
max. | 350 °C |
Heating capacity at 400V | |
Standard | 10 KW |
Standard | 20 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Cool water quantity | 20 l/min |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM3 |
max. flow quantity | 80 l/min |
max. pressure | 11 bar |
Capacity | 2,8 KW |
Oil tank | |
Capacity | 35 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 3/4" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 500 mm |
Height | 1300 mm |
Depth | 1120 mm |
Weight | |
Standard | 320 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter
- PC-Program
Further options and attachments on request
5222 bis 350°C
Circuits | |
Number | 2 |
Flow temperature | |
max. | 350 °C |
Heating capacity at 400V | |
Standard | 20 KW |
Standard | 30 KW |
Standard | 40 KW |
Cooling capacity | |
Cooling water temperature | 20 °C |
Flow temperature | 170 °C |
Δ T | 150 K |
Cool water quantity | 20 l/min |
Standard | 20 KW |
Standard | 40 KW |
Standard | 60 KW |
Pump capacity | |
Typ | PM3 |
max. flow quantity | 80 l/min |
max. pressure | 11 bar |
Capacity | 2,8 KW |
Oil tank | |
Capacity | 35 l |
Regulation | |
Standard | Flow |
Optional | Return flow |
Optional | External |
Connection voltage | |
Standard | 400V/50Hz 3PE |
Connections | |
System circuit | 3/4" |
Cooling water circuit | 1/2" |
Dimensions | |
Width | 695 mm |
Height | 1300 mm |
Depth | 1120 mm |
Weight | |
Standard | 348 kg |
Basic equipment:
- Peripheral pump with magnetic coupling and ceramic shaft
- Fully automated ventilation
- Dry run protection
- Internal bypass
- Manometer in flow
- Sturdy tubular frame
- Detachable casing
- Colour blue/grey
- Control cabinet IP54
- Enforced heating and cooling system
- Ceramic insulation
- Cold oil chamber
- µP128 micro process control with multilingual plain text display
- Simple handling
- Target/actual temperature display
- Setpoint switching (Start/Production)
- Cooling with automatic stop
- Timer switch
- Operational hour meter
- Service interval
- Flow monitoring
- Oil back suction
- Leak stop operation
- Malfunction and warning information with code and plain text
- Sensor break monitoring
- Overheating protection for thermal oilMonitoring of the maximum and minimum set value
- Integrated storage model
- Error log with date and time
- Energy-saving mode
Options:
- Oil back suction with automated ventilation
- Blow fiixture Cooler
- Return flow sensor
- Level monitoring (min, min warning, max.): red light, white
- Oil filling front
- Oil-tank lid self-closing
- Flow measurement 4 - 50 l/min
- Automatic oil filling front
- Optical level display
- Plexiglas front cover
- External switch-on connection
- External sensor connection (Fe/CuNi)
- External sensor connection (PT100)
- Interface RS485
- Moulding cycle-Break
- Central malfunction indicator: red light
- Central malfunction indicator: plug
- Central malfunction indicator: Horn door
- Central malfunction indicator: sound generator lid
- Operating status indicator: green light
- Operating status indicator: plug
- Interface Profibus external (up to 8 circuits)
- Interface Profibus internal
Attachments:
- Connection cable
- Installation kit system circuit
- Installation kit cooling water connection
- Pump protection with filter element
- Pollution display with pump protection filter